Biolin Attension Tensiometer
Mettler Toledo DMA 1
The Mettler Toledo DMA 1 system is a 10 N maximum environmental DMA capable of both strain and stress controlled sinusoidal loading. Conventional thermal-mechanical DMA and static mechanical testing can be done in atmospheric conditions from 25 to 600 degrees C. Submersion testing can be performed in a variety of solvent systems with bath controlled heating and cooling from -5 to 80 degrees C. Crash cooling liquid nitrogen allows the system to perform testing down to -190 degrees C.
ATS Rheosystems Black Pearl Viscometer
Biolin Q-Sense
The Biolin q-Sense QCM-D system provides detailed settlement information for applications like protein adhesion, adsorption and film growth applications. The dispersion functionality allows for mechanical assessment of systems which are responding dynamically.
B&W Tek i-Raman system
Shimadzu IR Prestige
SpectraMax M5
BL2 Access Requirements
Horiba FluoroMax 4P Fluorometer
PicoQuant FluoTime 100
BL2 Access Requirements
Zetasizer Nano ZS DLS
The Malvern Zetasizer Nano ZS uses photon correlation spectroscopy (PCS), which determines particle size by measuring the rate of fluctuations in laser light intensity scattered by particles as they diffuse through a fluid, for size analysis measurements and electrophoretic light scattering (ELS), which determines electrophoretic movement of charged particles under an applied electric field from the Doppler shift of scattered light, for zeta potential determination.
Shimadzu UV-2550
The Shimadzu UV-2550, with it's double-blazed grating, double monochomator design, provides a high-energy throughput optical system with ultra-low stray light. While featuring low stray light, excellent energy characteristics are provided over an extremely wide wavelength range (200 - 1100 nm), from the ultraviolet to visible, and into the near infrared for both liquid and solid samples.
Olympus FV 1000 Confocal and Picoquant TCSPC Instrumentation
Both 405 nm and 640 nm pulsed laser sources allow for fluorescence lifetime imaging microscopy (FLIM) on the FV 1000 platform using a PicoQuant TCSPC FLIM add-on. Two detectors allow for two color FLIM or for anisotropy decay imaging (A-FLIM).
BL2 Access Requirements
Bruker LUMOS II
Wide field IX70
Bruker Xtreme 4MP
The Xtreme system combines high-sensitivity optical and radiographic molecular imaging (Biolumenescence and Fluorescence) with high-resolution digital x-ray to deliver precise anatomical localization of molecular and cellular biomarkers in vivo. Magnified x-ray capabilities allow for x-ray imaging of small species such as zebrafish with high resolution and contrast. Software automation simplifies complex multimodal imaging protocols. The system includes animal handling features such as a heated sample shelf, a gas anesthesia system and a MARS 360-degree animal rotation system.